Post Job Free

Resume

Sign in

Project Manager Mechanical Engineer

Location:
Khuzestan, Iran
Posted:
April 20, 2014

Contact this candidate

Resume:

Name: Ali Ghassemi

Education: Bachelor in Mechanical Engineering, Design, from Open University

Of Ahwaz, Iran

Birthday: August 16th, 1984

Location: Flat No. 22, 17Eghbal Street, Kouye mellat, Ahwaz, Khuzestan, Iran

Computer Knowledge: Solid Works (Professional), AutoCAD, Excel, Word,

outlook

Experiences:

Work as a Mechanical engineer, designer and Mechanical drafter from

1.

2011 since, in Technical and engineering services company of Nasr

Mobtakeran.

Project Manager of Slime line subsurface safety valve 7” x 9 5/8”, 26# with

2.

Equalizing system.

Supervision during assembly of equipment.

3.

Designing Slime line subsurface safety valve 7” x 9 5/8” with equalizing

4.

system with SolidWorks.

Design GS Pulling Tools, Protection sleeve and Isolation sleeve suitable for

5.

Subsurface Safety valve 7” x 9 5/8” with SolidWorks.

Designing a thread for slime line subsurface safety valve 7” x 9 5/8” size for

6.

its internal connections which endures 10,000 PSI pressure.

Designing Liner hangers and their accessories like Landing collar, pump

7.

down plug, wiper plug, setting tools, slick joint, hanger(single and Double

Cone), Top set packers (mechanical Set), Pack off sub and pipe joints, in 7”,

9 5/8”, 11 ” and 16” Sizes.

Designing Float Shoe and Float Collar in All Sizes like 4 ” (used for Liner

8.

Hanger), 5” (Used for Liner hanger), 7”, 9 5/8”, 11 ”, 13 3/8”, 16”, 18

5/8”, 20”, and 30”.

Designing two Stage Cementing Accessories include Hydraulic and

9.

Mechanical Cement stage Collars both in sizes 7”, 9 5/8”.

Familiar with Internal Flush (IF), Short Line Casing, Buttress (BTC),

10.

ACME (Stub ACME and General ACME), UN Group Threads (UN, UNF,

UNS, UNC, UNEF) and NPT Connection according to their Referred

standards.

Design manager and project manager of stinger stab in latch in, suitable for

11.

using in Float Equipment.

Drafter of slime line subsurface safety valve7” x 9 5/8’’, isolation sleeve,

12.

protection sleeve, Pulling GS, stinger stab-in latch in, Liner hangers and

their all accessories, float shoes, float collars, Two stage cementing

accessories( mechanical and hydraulic type) and Permanent and Retrievable

Whipstock.

Simulating Equipment in SolidWorks Simulator to make sure of safe

13.

function of tools during applying the forces and pressures in real

environment.

Draftsperson of Internal Flush (IF) threads, Short line casing, Buttress

14.

(BTC), General and Stub ACME Threads According to referred standards.

Design New Equipment, Make 3D Parts, do assembly in SolidWorks, Check

15.

& Edit old Drawings, Apply tolerance for Dimensions.

Proficient to work with Calipers, micrometers (internal & External) and

16.

other measuring equipment.

Language Skills: Persian (Native), English (Average),

Email: acdrv1@r.postjobfree.com

Phone: +989*********

+986*********



Contact this candidate