***** ****** **** (740)
Ashville, OH 43103
accqy4@r.postjobfree.com
Objective: Director of Operations/Facilities Manager
HIGHLIGHTS OF QUALIFICATIONS
* Conscientious and creative; willing to assume responsibility
* Exceptional talent for innovative problem solving under pressure
* Highly effective in communication with engineers, technicians and
translating information
* Extremely dependable in completing projects accurately and on time
* Dedicated, professional attitude, highly creative and resourceful
* Easy to work with, as well as a cooperative and supportive of colleagues
* Ability to get the job done, hold expenses down, increase profitability
and minimize downtime
* Able to maintain high team motivations
WORK EXPERIENCE
Grubb-Ellis/ Jones Lang LaSalle 306 Grief Parkway, Delaware, OH 43015
. Senior Chief Engineer of Data Center Operations September 2007 to
Present
. Implement the preventative maintenance program on equipment throughout
entire campus 65 acre facility, utilizing the tenants work order software
system (REMS)
. Provide support for invoice processing and develop subordinates skill
sets on CITREX system
. Assure quality, process improvements for 100,000 Sq. Ft raised floor for
tier 4 data center relating to controls and HVAC upgrades and continuous
maintenance improvements
. Manage and supervise the operations of the plant utility equipment
including, Chilled water closed loop system, utilizing six - 1,000 ton
Trane Chillers and 14 up-draft Cooling towers for the open loop system.
. Implement engineering projects concerning electrical, calibration and
mechanical support
. Interact with suppliers of equipment, engineering services and
construction and related services
. Coordinate the implementation of Facility requests and developed an
effective project plan for whip requirements and on time installation,
respond to tenant complaints and resolve
. Ensure the completion of monthly preventative maintenance of the
facilities equipment
. Audit the facility personnel profiles and perform performance
evaluations
. Compile monthly report data as related to time sheets and operations
of the facility
. Develop business controls for operations in maintenance areas. (Daily
round log sheets) etc...
. Responsible for conducting staff meetings, monthly budget, compiling
employees' time
sheets, work schedules and submitting to pay roll
. Coordinate and instruct training programs as required for engineering
and maintenance
personnel
. Ensure the staff has an understanding of building safety and fire
alarm systems
. Composed 7 x 24 x 365 a day work schedule to minimize the overtime at
the Data Center
. Procurement of facilities supplies and materials to maintain daily
operations
. Coordinate vendor repairs, assure all repairs have been fulfilled and
submit reports
regarding equipment failures
. Maintain the operation of all critical equipment at the 305,000 Sq ft
Data Center, including
(But not limited to), Generators, Chillers, UPS, ASTS, HVAC, BMS,
Parallel Switch gear etc.
. Implemented the Preventative maintenance and weekly running of 8 - 2,000
KW Detroit Diesel Generators and developed SOP'S to perform the in house
load bank testing procedure
Continuous of Joe Childers current work experience
. Responsible for all direction, coordination, implementation, execution,
controls and completion of projects while being consistent with company
strategy, commitments and goals.
. Coordinate and ensure compliance with municipal licensing requirements,
including operating permits, inspections, etc
. Manage contracts for maintenance including (but not limited to) grounds
maintenance, security, snow removal, cleaning contractors, etc.
. Oversee and prioritize all plant maintenance request, applying sound
engineering and reliability principles
. Responsible for the storage of supplies and material for the in house
stock rooms
. Disperse tools and equipment for Engineers and developed shop
protocols
. Search, interview, hire and terminate employees
PharmaForce Inc, 4150 Lyman Drive, Hilliard, OH 43026
. Facilities Engineering Manager August 2005 to September 2007
. Created programs to perform preventative maintenance on equipment
throughout the facility
. Assured all capital projects, maintenance instrumentation, validations
and calibration actions preserve the integrity and effectiveness of
production systems
. Proposed and assist implementation of quality, process, continuous
improvement and cost savings ideas in the production area
. Maintained Boilers for Facility, Clean Steam, pharmaceutical grade
compressed air, nitrogen systems and down line equipment
. Oversaw the installation of new and used equipment in Aseptic Sterile
Processes
. Provided technical support for all manufacturing production and filling
equipment
. Performed daily water sampling for High Purity Water System, chilled
water systems and cooling towers, evaluate test results per FDA
Requirements
. Created, write programs for the validation, including standard operating
procedures
. Assisted engineering projects when required with electrical, calibration
and mechanical engineering support
. Performed the scheduling, installation and coordination of engineering
work scopes
. Performed the daily scheduling for Electrical Maintenance Department
. Maintained Reverse Osmosis Water Purification System and WFI/RO system as
related to a sterile injectable manufacturing facility to create High
Purity Water
. Maintained all plant alarm system trouble shooting relating to card and
bar code scanners
. Oversaw Electrical, PLC, Pneumatics, and Hydraulics Systems, knowledge of
Auto Cad
. Successfully passed Federal Drug Administration inspection on the above
processes
. Provided calls and interacts great relations with vendors for resolving
larger facility maintenance issues and design changes needed and all
machine equipment updates, such as HVAC manufactured by TRANE for clean
room environments
. Oversaw and implement population on maintenance spare parts list into
system
. Worked closely with Plant groups and provides as needed site drawings
support and schematics
. Coordinated site contracts with vendors and maintained yearly
departmental budget
Joe Childers, Page 2
Ross/Abbott Laboratories, 585 Cleveland Ave., Columbus, OH 43215 (614) 624-
6225
. Senior Electrical Engineering, Automated Controls Technician I
June 1995 to August 2005
. Preformed validation testing for Air Emission Scrubbers
* Worked on HVA, MCC's and high voltage systems
* Assisted Engineering department on the installation of new equipment on
Aseptic Processes
* Provided technical support for all manufacturing production and filling
equipment
* Used RS Logix software to program processes and increase productivity by
upgrading and modifying Allen Bradley PLC-5, SLC-500 and Control Logix
processors
* Knowledge of Allen Bradley panel views and panel mates
* Performed preventative maintenance on instrumentation, chart recorders,
transmitters and control loops
* Worked on Allen Bradley process control interfaces, Data Highway, Device
net and Ethernet
* Experience with Modicons, Modbus and Modbus Plus
* Trained new employees on Plant Production Equipment
Ross/Abbott Laboratories, 350 N. Fifth St., Columbus, OH 43215
* Electrical Maintenance Technician January 1990 to
June 1995
* Performed preventative maintenance on equipment throughout the facility
* Repaired Eaton Ken way automated guided vehicles, Stacker retrieval
cranes, monorail trolley systems, forklifts, Simplex sprinklers and fire
alarms
* Maintained automated storage barcode application and radio communication
systems
* Responsible for the troubleshooting of all software and hardware
interruptions
Eastman Kodak, 1100 East Main Cross Street, Findlay, OH 45840
* Electrical Engineering Maintenance Crew leader
November 1987 to November 1989
* Maintained, performed troubleshooting and repaired automated film process
and developing equipment
* Performed instrumentation and calibration of process controls
* Assisted engineering department in the construction and design of new
equipment
* Trained employees on the operation of new equipment
* Reduced downtime by performing basic troubleshooting operations
OTHER SKILLS
. Very proficient with computers, including Windows-based software,
Allen Bradley software,
VFD's and Servo drives, initiate changes using GML Commander, use
standard application
Software such as Lotus notes, MS word and Excel.
. EDUCATION
DeVry University, Columbus, OH Graduated 1989
Electronics of Applied Sciences
3.9 GPA Presidential Honor Society
Joe Childers, page 3
CERTIFICATIONS
. Type I and Type II Refrigeration Certification
. Thermography Level I
COMMUNITY SERVICE
. Fourteen years of youth coaching experience with Teays Valley Youth
Athletic Association, including baseball, basketball and football.
. Current Mid Ohio Food Bank Volunteer
References available upon request for Joe Childers
Page 4