Post Job Free

Resume

Sign in

Electrical Maintenance

Location:
Athens, GA
Posted:
February 03, 2014

Contact this candidate

Resume:

NEAL A. KEETON

[pic]

*** ****** **. **********, **. 301**-***-***-

9289

WORK EXPERIENCE

HKA Enterprises (Oct 2012 - Present)

Anderson, South Carolina

* Electrical Controls

* Maintaining equipment

* Installation of new equipment

* General electrical maintainence

* Trouble shoot devices and motors when necessary per preventive

maintenance and standard maintenance procedure, replacing parts if

needed with the intentions of minimal down time as possible

* Install and work on equipment while energized with appropriate safety

equipment and proper precautions being taken on a daily basis

Shaw Construction (Oct 2010-Oct 2012)

Cliffside, North Carolina

* Industrial electrician, new construction for coal burning power

facility

* Installation of multiple size conduit, equipment, cable tray, etc...

* Duties consist of installing cable tray, bending conduit and

installing in duct banks as well as throughout facility

* Pull in cables ranging from high voltage cables (6.9,13.8, 4160 thru

#22 and below power, control, and signal cables)

* Build stress cones if needed read drawings and make all proper

terminations required by drawings, verify work is correct, fill out

paper work as required verifying work is correct and complete

* Set equipment such as switch gears for high voltage cables, DCS

cabinets, transformers, MCC's etc...

* Keep and maintain all proper safety training certifications as well as

equipment certifications

* Attend weekly and daily safety meetings, work and maintain job safety

according to OSHA standards on a daily basis

* Install and work on equipment while energized with appropriate safety

equipment and proper precautions being taken on a daily basis

* Transferred to commissioning/startup for instrumentation and controls

8-15-11 to present

* Obtain P&ID's for a particular system showing all devices, motors,

transmitters, valves, TE's, etc...

* Perform a wire check per the device and or motor from DCS/electrical

room to the device itself, verify that all terminations are correct

according to the wiring diagram and that the wire is labeled with the

proper label

* Use 375/475 device for calibrating transmitters and motors such as

MOV's, flow valves, flow transmitters, and PIT's

* Use of low and high pressure pump used to set high and low alarms for

pressure switches

* Once devices/motors are confirmed out in the field as in proper

working condition and all proper valves have been stroked it's tagged

as being commissioned and is ready for a start at the appropriate time

* Trouble shoot devices and motors when necessary per preventive

maintenance and standard maintenance procedure, replacing parts if

needed with the intentions of minimal down time as possible

TA Services Group (Nov 2009-2010)

Albany, GA

* Commercial and industrial control electrician

* HVAC controls, new construction as well as service work to existing

facilities

* Troubleshoot heating and air units, chillers, drives, air handling

units, etc...

* Instillation of new equipment as well as demolition of old equipment

* Instillation of conduit, pull in all power sources as well as control

wiring, terminate wiring and verify all equipment is operating

appropriately

Electrical Foreman (Jan 2008 - Feb 2009)

Fluor, Greenville, SC

* Responsible for 8-10 person crew

* Foreman responsibilities consisted of time keeping, assigning work

detail, attending project meetings, conducting weekly safety meetings

* Performed electrical duties for plant maintenance and shutdowns (2)

* Both shutdowns consisted of high voltage as well as low voltage

wiring, terminations, cable tray, and conduit installation, and plant

maintenance throughout the year

* Both projects completed before deadline and without any safety

violations

Industrial Electrician (July 2007 - Jan 2008)

AMEC/Kamtech, Tucker, Georgia

* Installed temporary power for offices, tool and job trailers

* Performed electrical duties for scrubber project at Plant Wansley

(coal burning power generating facility)

* Installed conduit, cable tray, cable bus, motors, and machinery

* Pulled low voltage and high voltage wiring and completed high voltage

testing using hi- pot machine ensuring cable had not been damaged

during the pulling process completed by making any and all proper

terminations.

* Prepared stress cones for high voltage cable (4160 volts), (13.8

volt) and terminated in power supply switch gears

* Set all 13.8 volt switches and 4160 volt switches for primary power

connection to be performed by utility company

* Completed all secondary side terminations as well as completed the

installation of the on/off lever which opens and closes the switch

providing primary power for the facility.

* Completed all control terminations on the DCS side as well as the

instrument side out in the field. Making all proper terminations

coinciding with drawing diagrams and prints.

Industrial Electrician (July 2006 - July 2007)

Conaway Electrical, LaGrange, Georgia

* Duties consisted of but not limited to preventive maintenance of wire

manufacturing facility. (Southwire)

* Removed old and installed new machinery while providing wire ways

using conduit and cable tray for new machinery cable instillation and

terminations.

* Located low voltage and high voltage problems throughout massive

plant.

* Highly skilled EMT and rigid conduit bending and installation of all

size.

* PLC and control wiring performed for machinery operation.

Maintenance Superintendent (July 2004 - February 2006)

West Central Technical College, Douglasville, Georgia

* Maintained 80,000 square foot facility. (Douglas Campus)

* Provided routine and preventative maintenance for all areas including

but not limited to Energy Management, Security, and Surveillance

Systems.

* Supervised maintenance and custodial staff, 5 employees.

* Provided input to Campus Manager in decision making regarding

improvement projects.

* Communicated via phone and email with vendors and clients.

* Purchased equipment and supplies for the department as needed.

* Proposed budget for fiscal year and maintains $100,000 budget for

department.

* Has Microsoft Office 2003 experience.

* Coordinate work to be performed and completed throughout the facility,

working with outside vendors excepting bids while providing specs and

scope of work for the contractor for work to be performed while

abiding by any and all OSHA safety guidelines.

Substation Assembler (August 2003 - July 2004)

Aubrey Silvey, Carrollton, Georgia

* Supervised work team in Key West, Florida too assemble substation

providing backup electrical power to the area.

* Operated heavy equipment/machinery and worked on high tension power

lines during project.

* Prepared and constructed stress cones to high voltage wire, to be

terminated within PDC on site as well as the provided power poles.

* Constructed underground conduit system within tight quarters puling

wire throughout the substation yard and up power poles making all

proper terminations for permanent power feed for the substation PDC.

* Installed battery backup systems and UPS to the substation for

generator backup in case of complete power failure. Complete

instillation consisted of forming up the slab for equipment to be set,

install conduit, pull cable, and make all proper terminations,

completing all cable testing before providing permanent power to

equipment.

Electrician (September 1999 -August 2003)

West Georgia Electric, Carrollton, Georgia

* Managed work crew to provide electrical services for residential,

commercial and industrial facilities

* Performed electrical work on high security surveillance systems.

* Install conduit of all sizes, underground and throughout facility.

* Install and mount panels, transformers, PLC cabinets, DCS cabinets,

MCC equipment as well as make all necessary terminations for proper

operation.

* Installed conveyer systems and maintain for processing industrial

facilities for production purposes.

* Coordinate work with facility personnel to be performed during

specific hours and back up and running for normal business hours.

OTHER ACCOMPLISHMENTS

* Completed ITS substation orientation

* Completed Arc Flash Training

* Completed 0200 orientation

* OSHA 10 certified - Certification current

* Equipment operator's license

* 2-man scissor lift (1000 lbs), AWP boom lift (500 lbs), 1 man lift

(375 lbs), Hyster-28000 lbs, telescopic 10,000 lbs, Forklift (500 lbs)

* 15 years electrical service without a safety infraction

EDUCATION

West Central Technical College,

Completed one year of Electrical Construction and Maintenance

program.

Heard County High School

Graduated May 1997

REFERENCES

Available upon request.



Contact this candidate