URS Energy and Construction (contract with Pfizer)

Worked at Pfizer site Cambridge as HVAC Lead technician: Schedule work assignments and PM work to staff, while receiving maintaining and completing work orders on Maximo system, work along side crew performing work on VAV boxes, chillers, heat pumps, roof tops, -80 & -20 freezers, boilers and package units. Scheduled and monitored subcontractors as needed. Monitor building controls using Andover Control Computer system, monitoring Critical Lab and Animal holding area temps and humidity as well as office areas. Customer relations. Covered handled and assigned emergency calls. Take care of 2- six story and 2-three story buildings. With 4- 120 ton chillers 1-140 ton chiller 1-60 ton chiller & 1-40 ton chiller. As well as Chilled water systems, Air Handlers, HVAC Equipment, Humidification, Rooftop and Split systems. And various other equipment.

5/2011-11/2011

Textron (Temporary Contracted Position, contract expired)

General PM and handled daily calls as well as emergency calls. Worked on package units, VAV units, boilers, and monitored DDC. Andover Controls energy management System for critical clean rooms Lab areas and offices. Work included, air handlers, rooftop units, Dampers, Diffusers, Sheet metal, and insulation, Valves both pneumatic and mechanical, chilled water systems, 4-100 Ton Chillers general maintenance. Air compressor general maintenance.

9/2010-2005, 1999 - 1996

Johnson Controls (8 years)

Leader of a crew of five, preformed Installation and performed PM on various equipment, at various City of Boston sites, worked on chillers, cold and hot water systems, VAV boxes, constant volume systems, split systems and package roof tops, boilers, natural gas and #2 fuel and all associated equipment. DDC and pneumatic controls, computers for building controls, customer relations. Boiler repair and maintenance of #2 & #4 fuel oil and nat. gas systems throughout Saugus and Marblehead schools and town building. Repairing and replacing pneumatic lines and controls as well as heating and A/C maintenance and repairs.

2002/2005, 2002 -1999 (7 years)

Emcore/J. C. Higgins, Randolph, MA (5 years)

In-house maintenance of several buildings at Wyeth Pharmaceutical of Cambridge. Troubleshooting of Carrier and Trane Chillers, Heat Pumps, VAV and Hot Water Systems, Split Systems, Clean rooms Package System and servicing other various equipment including Andover Control Systems. Responsible for building and equipment inspections and data recording, Preventive Maintenance and customer relations.

Troubleshooting/repairing/preventive maintenance of heating and A/C units. PM tear down of manufacturing 12 & 6 cylinder Vilter compressors and on FES open drive compressors. Performed winterizing on Trane and Carrier comfort cooling chillers. Worked on 454 water cooled natural gas open drive compressors. Installed package roof top units.

CERTIFICATIONS: EPA Certified # 148*******

OSHA 10 Construction Safety & Health

Refrigeration Technician License # RT-019907

Ward manufacturing gas Certificate # 003675

Defensive Driving Course # 4942855

ASE Refrigerant Recovery & Recycling Certification