Post Job Free

Resume

Sign in

Plant Testing

Location:
Islamabad, Islamabad Capital Territory, Pakistan
Salary:
3000 US Dollar
Posted:
September 21, 2013

Contact this candidate

Resume:

M K ASH I F SHABB I R

(NDT AND PLANT I NSPECTOR )

Cell #: +92-302*******

E-mail : m ab8bah@r.postjobfree.com

OBJECT IVE

Looking for a position in a dynamic and well reputed organization, which offers good

opportunities and challenging working environment, this in turn would help to enhance my

knowledge, experience and future prospects.

WORK ING EXPER INCE

5 year experience in the field of NDT and Plant inspector.

(1)Engro Fertilizer Private Ltd.Dharki

4 year experience in Engro Fertilizer as a NDT and Plant Inspector.

(2)Engro Polymer and Chemical Ltd. Karachi

1.01 year experience in Engro Polymer and Chemical Ltd Karachi.

PROFESSIONAL QUAL I F ICAT ION

2.

Apprentice training From Engro fertilizer plant In (NDT inspector & Inspection

1

Technician)

Levels II in UT from American Society of non destructive Testing

Levels II in RT from American Society of non destructive Testing

Levels II in MT from American Society of non destructive Testing

Levels II in PT from American Society of non destructive Testing

Welding inspection COURSE Training from PAKISTAN WELDING INSTITUE

Computer software’s from Infosol Computers Karachi

ASME SECTION V TRANING FROM SGS Company

Cathodic Protection Pertosult & unimart

Safety competition (winner) From Engro fertilizer Plant

ACADEM IC QUAL I F ICAT ION

B.S.C from khawaja fareed post graduate college Rahim yar khan.

A REA OF EXPERT IES AND ABIL I T I ES

Extremely reliable and dependable (Strive for quality & high personal standard)

4

Methodical and rigorous approach (achieving task & objective)

5

Excellent interpersonal skills (Good communicator, leadership, high integrity)

6

Seeks new responsibility and uses initiative (Self- sufficient)

7

Set up and utilize nondestructive testing equipment and Calibrate nondestructive test

8

equipment.

Conduct tests to ensure quality or detect discontinuities (defects) using NDT methods of

9

inspection.

Establish techniques for proper examination of objects under inspection, ensuring strict

10

adherence to safety regulations.

Apply testing criteria in accordance with applicable specifications or standards and

11

evaluate results.

Experience in report writing

12

NDT EXPERT I ES

All bellow NDT Jobs Perform as very expertises

Dye Panetrant Testing (with solvent removable, florescent and water washable Panetrant)

Magnetic Particle Testing (with by permanent and electromagnetic yoke

Ultrasonic Flaw Detection (with FD-410S & DT-2000)

Scan welds joints with ultra sonic Equipments and also checks the piping thickness

Radiography PERFORMS with Iridium 192 and Cobalt 60 SOURCE.

Thickness Measurement with Ultrasonic Testing (with DM2, DM4, DME-DL Data

Logger,37Dl Plus, 38DL plus)

Hardness Testing (with Equitip Schneider, TH130 Times)

Leak Testing (By SFT, Pneumatic Test, Ammonia Test)

Hydro testing (of Vessels, Exchangers, Pipelines, valves)

Positive Material Identification (with innov-x x-ray Analyzer)

Holiday Detection (with Tinker & Rasor)

Visual Inspection / Videoscopic Inspection (with karl-storz)

PSV Calibration Testing and PSV hot setting

Welder’s Qualification Tests

Cathodic Protection Monitoring

Welding Inspection, Corrosion Inspection

W ELD I NG I NSPECT ION

N ature of work

Welding inspection of CS, SS, and ALLOY STEEL piping according to WPS.

Reviewing the test procedure, welding procedure specification, PQR, WQT, method and

statement.

Witness and procedure qualification testing and qualified welder in both manual and

automatic welding.

Checking the according criteria as per codes and process and standard specification

(ASME B31.3, API 1104)

Preparation of NDT test plan and inspection test and plan.

Preparing test packages as per component list and line class.

Inspection of the Pre Heating, inter pass temp and post weld heat.

Check the essential Parameters as per the WPS requirements and quality procedure.

Visual and Gauges inspection in Fit-up before and after welding.

To check the proper electrodes are used for the respective material and tem has been

maintained as per electrode manual.

Qualify the welders as per the project requirement.

Inspection of Pressure vessels, Heat Exchanger, Columns and Boilers.

PMI jobs perform on incoming material and also know about metallurgy of material.

P IP I NG I NSPECT ION AND T H ICKNESS MON I TER ING

Detailed Thickness Monitoring of In-service critical piping to ensure reliable and

i ncident free Plant Operation. . Using instruments PANAMETRICS 36 DL PLUS,

D M4DL & CYGNUS.

In case of any leakage, verify WPS for box-up.

External visual inspection of pipelines to see any rust / corrosion and also the

condition of pipe supports especially of steam network.

Inspection of Corrosion under Insulation.(CUI)

Calculation of Pressure Design Thickness, Cor rosion Rate and assessment of

R emaining Life for safe operation of Piping.

STAT IONARY EQU I P M ENT I NSPECT ION

VESSELS / COLOU MS / TANKS / H EAT EXCHANGERS /

B O I LERS .

Detailed internal inspection of above mentioned stationary equipments in Annual

T/A for any Pitt ing,Rusting,Corrosion,Cracks and preparation of inspection reports

maintaining of inspection history for record and recommending repair procedure as

per code and standard for safe reliable service of plant equipment.

Ul t rasonic Thickness monitoring of in service vessels/columns/shells of heat

exchangers and tank of continuous condition monitoring.

Witness of Hydrostatic and Pneumatic Leaks Testing.

Apply NDT methods such as DPT, MPT, Ult rasonic thickness measurement where

required.

Calculation of Pressure Design Thickness, Cor rosion Rate and assessment of

R emaining Life for safe operation of Equipments.

KNOWLEDGE OF CODES AND STANDARD

(1) API 510 (2) API570 (3) API 527 (4) API

572

(5) ASME SECTION IX (6) ASME SECTION V (7) ASME B31.3

E XPER IENCE OF ANNUAL TRANAROUND

NDT Inspector in Shut Down 2008 to 2009 in Engro Fertilizer Private L imited

NDT Inspector in Shut down 2009 in FFBL.

NDT Inspector in Shut down 2011 in FFC.

NDT inspector in shut down 2012 in Engro Polymer.

SPOKEN LANGUAGE

(1) English (2) Urdu

PERSONAL I N FORMAT ION

Father’s Name : Ghulam shabbir noori

Date of Bir th : 25 Dec 1986

CNIC # : 31304-2236740-5

Nationality : Pakistani

Religious : I slam

M ar ital Status : Single

Passport # : BK5137401



Contact this candidate